Main
   About
   Products
   Addressable Fire Alarm  Systems NEW
   Support
   Contact us


Support

  25 Ulyanovskaya str.  
410056 SARATOV Russia
Tel          +7 8452 22-11-40
               +7 8452 73-58-08    
              ext. 209, 211, 213  

Contact info

Head-office
25 Ulyanovskaya str.
410056 SARATOV Russia
Tel          +7 8452 510-877
Tel/Fax   +7 8452 222-972
Fax         +7 8452 222-888
 
Office
21 Ozernaya str.
119361 MOSCOW Russia
Tel           +7 495 437-52-07
Tel           +7 499 730-14-52
Fax          +7 499 730-15-04


Addressable Fire Alarm Control Panels


Price ListWebinarForumDownload  ICQ 425-764-479
 +7 (845 2) 22-11-40



The addressable fire alarm control panels are used to receive, process and record the information which comes from addressable devices. Panels form different signals of indication and control. All the control panels support the feeding of the addressable smoke, heat detectors and manual call points through the two-wired signaling line. The panels use the RS-R protocol and work through the RS-485 interface.
Àäðåñíûå ïîæàðíûå ïðèáîðû

The addressable signaling line is used for information exchange between the control panel and addressable devices. All the addressable devices have individual address in the signaling line. The addresses are assigned to the addressable devices by means of the programmer PKU-1. You can connect to the panel up to 500 addressable devices. The control panel polls the addressable devices according to the address data base. In response to the control panel’s request the addressable device transmits a coded send about its status. The addressable fire alarm control panels record the dust / smoke level of each addressable smoke detector in %. The control of the dust level can be carried out by the programmer PKU-1, by the software FireSec Operator or by the control panel in real-time.

For medium and big projects with the number of addressable devices more than 500 and where it is necessary to make gas or powder firefighting we recommend using the FAP “Rubezh-2AM”.

Download standard design for FAP "Rubezh-2AM"

Ðóáåæ 2ÀÌ

For objects where it is necessary to build the system of water firefighting we recommend using the addressable fire alarm panel “BUNS-01”.

Download standard design for BUNS-01

ÁÓÍÑ-01

The configuration of addressable fire alarm control panels is made by using the software FireSec Administrator which is supplied with the panels free of charge.

Download FireSec Administrator description

The on-line control of the protected area is carried out by means of the software FireSec Operator.

Download FireSec Operator description

Download the software Rubezh_FireSec_3_8

 
Copyright 2005-2006 Rubezh. All rights reserved.