Main
   About
   Products
   Addressable Fire Alarm  Systems NEW
   Support
   Contact us


Support

  25 Ulyanovskaya str.  
410056 SARATOV Russia
Tel          +7 8452 22-11-40
               +7 8452 73-58-08    
              ext. 209, 211, 213  

Contact info

Head-office
25 Ulyanovskaya str.
410056 SARATOV Russia
Tel          +7 8452 510-877
Tel/Fax   +7 8452 222-972
Fax         +7 8452 222-888
 
Office
21 Ozernaya str.
119361 MOSCOW Russia
Tel           +7 495 437-52-07
Tel           +7 499 730-14-52
Fax          +7 499 730-15-04


Addressable Detectors


Price ListWebinarForumDownload  ICQ 425-764-479
 +7 (845 2) 22-11-40



Addressable fire detectors produced by Rubezh, Group of Companies are technically complex devices used for detecting the fire at the early stage of smoke formation and ignition. Fire detectors allow to control several parameters in real time which are transmitted to fire alarm control panels. Control panels analyze the data, checks the detectors’ work if it is correct, fulfill actions according to embedded algorithms and form the control and indication signals. To improve the information exchange between detectors and control panels we developed our own universal protocol RS-R.
Àäðåñíûå ïîæàðíûå èçâåùàòåëè
 

At present time we produce the following types of fire detectors:

Standard execution
  • AFD-S 64 addressable optoelectronic smoke detector
  • AFD-H 29A2Raddressable differential-peak heat detector (64-76 °C)
AFD-S 64
To set the parameters to the detectors we developed a programmer PAD-01. Using this programmer you can:
  • check and change parameters: address, configuration, delay, holding, the date of the last technical service, activation threshold ∆Ò/t;
  • check parameters: dust level, serial number, indication mode, software version;
  • refine the dust level of detectors after you clean it.
PAD-01
Signaling line to which the detectors are connected can have both radial and circuit construction. Topology of the signaling line represents a “bus” with branching possibility. Maximum resistance of all the signal line wires should not exceed 100 Ohm, specific electrical capacity of the line not more than 0,5 nF/Ohm.
To detect a place of short circuit in the signal line Rubezh developed a line insulator IS-1 IS-1
Accessories for the detector’s installation:
  • A set of installation parts SIP-4 for installation to false ceiling;
  • Optical tester OT-1 to test the work of fire detectors.
Optical tester OT-1

 
Copyright 2005-2006 Rubezh. All rights reserved.